Status |
---|
subtle | true |
---|
colour | Blue |
---|
title | administrator |
---|
|
...
Image AddedGlobal options in FactoryLogix Office affect how users interact with FactoryLogix features and functions and control all aspects of the system. Global option settings combined with
...
user roles and permissions allow different types of access to all areas of the system. Administrators access FactoryLogix global options in the Settings area of the FactoryLogix Office client application.
...
...
...
Only a member of the Administrator group can configure default values for global options.
In the Process Planning category, you configure the default global option settings for all aspects of processes and process revisions including approval strategies, material assignments, and process revision options.
...
|
---|
Tip To search for a global option, select a column header on the right side of the window, then press Ctrl+F. In |
...
...
box that displays at the top of the window, enter a search string, then press Enter. All categories containing the search string you entered are highlighted in Yellow. (Select the Close button to end the search and redisplay all |
...
Category | Sub-category | Description |
---|
...
...
Process Planning | Process Approval Strategy
| Require One or More Assigned Defects Before Just-In-Time Flow Approval - When set to True, the system will require at least one defect at a Just-In-Time operation prior to allowing the release of the JIT operation to production. Require Default Location to Release to Production - Specifies whether a process revision must have a default location specified before it is released to production. Require Approval to Release to Production - When set to True, a process must go through an approval process before it is released to production. Require Approval for Just-In-Time Reroute Flows to Release to Production - When set to True, Just-In-Time reroute flows must go through an approval process before being released to production. Copy Initiator on Approval Notifications - When set to True, copies the original initiator on all emails generated by approvals, including auto-generated emails such as escalations.
|
...
...
True, setting a process to Approved will also cascade down the approval list for all points which that user is a member of. Automatic Release to Production - Specifies how the system behaves with respect to releasing to a process to production automatically when all required approvals for the process have been obtained. The process type can be Production, Receiving, or JIT (Just In Time).
|
...
...
|
Process Planning | Material Assignments
| Show Entire BOM When Making Part Assignments from Within an Operation - When set to True, the entire BOM is displayed for material assignments. Show a Warning When the Same Reference is Assigned to Multiple Operations - When set to True, displays a warning when material items are assigned to more than one operation. Enforce Quantity on Activity Assignments - When set to Error, the quantity at the activity level cannot exceed the quantity at the operation level. When set to Warning, a warning message appears, but you can ignore the assigned quantity. When set to Ignore, the assigned operation quantity is ignored. Auto Route Materials - When set to True, materials are assigned to operations automatically. Allow Part Assignments to Multiple Operations - When set to True, part assignments can be assigned to multiple installation type process steps.
|
...
...
|
Process Planning | Checkout Management
|
...
| Require recording of Process Planning change reason - When set to True, the user is prompted to enter an explanation of the changes made before exiting the Process Editor. Record Audit Log at Check In - When set to True, prompts users to enter a comment upon check in. Prompt for Check In on Self Checked Out - When set to True, prompts a user to check in an item that the user already has checked out when attempting to check out a conflicting item.
|
Process Planning |
...
...
...
...
...
...
Process Planning | Work Instruction Batch Printing | |
...
|
Process Planning | Document Revisioning | |
Process Planning | Revision Options |
...
...
- Server Address - Specifies the IP address or name of the server hosting the Wonderware Data Historian database.
- Database Name - Specifies the name of the Wonderware Data Historian database on the specified server.
- User Name - Specifies the name of a user in the Wonderware Data Historian database who can log in and make server calls.
- Password - Specifies the password for the user defined in the User Name setting.
...
- Default Validations - Defines the default settings to be used by all new instances of the Sub-Assembly activity, as well as those to use when replacing a serialized sub-assembly that was recorded without the use of the Sub-Assembly activity.
...
- Allow Selection of NCR and JIT Default Templates - When set to True, enables a hidden tab that allows users to specify default routing values for just-in-time (JIT) approval processes and non-conformance report (NCR) pathways.
...
- Added Color - A characteristic, specification, or document introduced on the current node of the tree will display in the selected color.
- Inherited Color - A characteristic, specification, or document that is inherited unchanged from the parent node will display in the selected color.
- Override Color - A characteristic, specification, or document that is inherited from the parent node and then changed will display in the selected color.
...
- Controls the display of a Just-in-Time (JIT) flow. When set to True, only the selected JIT flow and its associated reroute flows and Out of Route (OOR operations) will be displayed in the tree view along with the main process flow.
...
|
Process Planning | Part Library | Unit of Measure for Weight Properties - Identifies the unit of measure for the Weight property for Internal Part Numbers, variant part numbers and box definitions, and the Box Weight value on packout labels. Prompt for Password when modifying Documents of Assemblies with releases Processes - When set to True, activates a password prompt and records an audit log entry when a document is added to or removed from an assembly with a released process in the Part Library. IPN Field Limit Length - Sets the field length limit to a numeric value (the default value is 400). The range of values allowed is 0 to 400. When this value is set to 400, no validation is required. Any value less than 400 enables validation against an Internal Part Number field length.
|
...