Supported CAD file types
You can import a variety of CAD files into FactoryLogix. The following topics provide the parameters and beginning file headers required to import each type of CAD file.
Note
In addition to support for electronic computer-aided design files (ECAD),FactoryLogix also provides support for mechanical computer-aided design files, often referred to as 3D CAD or MCAD. For details, see Work with 3D CAD in FactoryLogix.
Altium Designer
Item | Description |
---|---|
Extraction procedure | Schematic and PCB design files can be exported into various formats - including previous versions of Altium's software or alternate software packages. Export of files is performed using the File > Save As command, or the File > Save Copy As command. |
Common file extension | *.PcbDoc |
Save as type | Altium PCB ASCII (*.PcbDoc) |
FactoryLogix import type | Protel 98/99/2000 ASCII PCB File (v3.0) |
Beginning file header | |RECORD=Board|SELECTION=FALSE|LAYER=UNKNOWN|LOCKED=FALSE
|POLYGONOUTLINE=FALSE|USERROUTED=TRUE|UNIONINDEX=0|
FILENAME=C:\Altium\PROJECTS\2ASCII.PcbDoc|KIND=Protel_Advanced_PCB
|VERSION=5.00|DATE=7/14/2009| TIME=2:17:54 PM|....... |
Note
The format of the CAD file must be Version 3.0 or higher and in ASCII format.
Cadence Allegro
Item | Description |
---|---|
Extraction procedure | Cadence Allegro requires the use of a script available from www.aiscorp.com. The script produces a ccam.cad file that you can import into FactoryLogix. |
Common file extension | *.cad |
FactoryLogix import type | Cadence Allegro (Aegis Script) |
Beginning file header | A!REFDES!CLASS!SUBCLASS!COMP_DEVICE_TYPE!COMP_PACKAGE!SYM_ROTATE!
PIN_NUMBER!DRILL_HOLE_NAME!NET_NAME!PIN_X!PIN_Y!
START_LAYER_NAME!END_LAYER_NAME!GRAPHIC_DATA_NAME!
GRAPHIC_DATA_1!GRAPHIC_DATA_2!GRAPHIC_DATA_3!GRAPHIC_DATA_4!
GRAPHIC_DATA_5!GRAPHIC_DATA_6!GRAPHIC_DATA_7!GRAPHIC_DATA_8!
GRAPHIC_DATA_9!GRAPHIC_DATA_10!SYM_NAME!SYM_X!SYM_Y!SYM_MIRROR!
J!D:\cam\102.brd!Tue Apr 25 15:21:27 2000!-100.000!
-170.000!500.000!430.000!0.001!millimeters!B01!
47.2 mil!6!OUT OF DATE!S!!BOARD GEOMETRY!OUTLINE!!!0.000!!!!!!!!
ARC!-8.095!-9.949!-8.095!-9.949!-10.000!-9.949!1.905!0.000!
COUNTERCLOCKWISE!NOTCONNECT!TARGET!-10.000!-10.000!NO!
|
Note
A Cadence Allegro file can be distinguished easily by the ! characters in the output file. 29 data fields are required in the output file.
Cadence OrCAD IPC-2581
Item | Description |
---|---|
Common file extension | *.xml |
Beginning file header | <?xml version = "1.0" encoding = "UTF-8"?>
<IPC-2581 revision="A" xmlns="http://webstds.ipc.org/2581" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"> |
Eagle Layout Editor
Item | Description |
---|---|
Extraction procedure | Visit www.cadsoft.de – Download User Language Programs (ULPs). Download the gencad.ulp. |
FactoryLogix import type | GENCAD |
GenCAD v 1.4 from Veribest
Item | Description |
---|---|
Extraction procedure | Veribest provides a stand-alone application called Report Writer. Use this application to export the Mitron export option, which causes Veribest to produce a GenCAD compliant output ASCII file. |
Common file extension | *.cad |
FactoryLogix import type | GENCAD |
Beginning file header |
|
IPC-D-356
Item | Description |
---|---|
Common file extension | *.net or *.356 |
FactoryLogix import type | IPC-D-356 file |
Beginning file header |
|
Mentor Graphics Expedition
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | *.cad |
FactoryLogix import type | GENCAD |
Beginning file header |
|
Mentor Graphics Neutral File
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | *.neu |
FactoryLogix import type | Mentor Graphics |
Beginning file header |
|
OrCAD
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | *.cad |
FactoryLogix import type | OrCAD GENCAD file |
Beginning file header |
|
PADS
Item | Description |
---|---|
Versions |
|
Extraction procedure |
|
Common file extension | *.asc |
FactoryLogix import type | PADS PowerPCB/Perform/Works |
Beginning file header |
|
P-CAD (method 1)
Item | Description |
---|---|
Versions |
|
Extraction procedure |
|
Common file extension | *.pcb |
FactoryLogix import type | P-CAD PDIF |
Beginning file header |
|
P-CAD (method 2)
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | |
OLD extraction procedure |
|
Beginning file header |
|
PROTEL 98/99 ASCII PCB File Version 3
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | *.pcb |
FactoryLogix import type | Protel 98/99/2000 ASCII PCB File (v3.0) |
Beginning file header |
|
SCI Cards Neutral File
Item | Description |
---|---|
Extraction procedure | For FactoryLogix, you must extract a SCI-Cards Neutral file. |
Common file extension | *.cii |
FactoryLogix import type | SCI-Cards Neutral File (*.cii) |
Tango for DOS
See PCAD .pcb export.
Item | Description |
---|---|
FactoryLogix import type | Tango DOS PCB |
Valor ODB++ Cad Project
Item | Description |
---|---|
Common file extension (supplied by customer) | *.tar or *.tgz |
FactoryLogix import type | Valor ODB++ |
ZUKEN VISULA and CADSTAR
Item | Description |
---|---|
Extraction procedure |
|
Common file extension | *.paf |
Import | CADstar is capable of outputting the CADIF file format. Use the output option for CADIF and import via the FactoryLogix Visula/CADIF interpreter. |
FactoryLogix import type | Zuken CADIF |
Beginning file header |
|
Copyright © 2024 Aegis Industrial Software Corporation. All Rights Reserved.