Comprehensive Data Import (CDI - Includes Full Library Support) properties
The following information is based on selecting the Comprehensive Data Import (CDI - Includes Full Library Support) Generated Program Format in the Properties dialog. The dialog tabs contain options to define a location to store the GSM required information (part numbers, feeders, components, and configuration).
Generated output format | Tab | Option |
---|---|---|
CDI - Includes Full Library Support | General |
Library Database - Specifies the type of library database the Universal machine will access: Access Database Type or System DSN Type.
Display Units - The units that FactoryLogix will display in the machine programming interface (Inches, Mils, or Millimeters). Output Units - The units that will be used in the output file (Inches, Mils, or Millimeters). Generated Program Format - Select the output format to generate from FactoryLogix (in this case Comprehensive Data Import (CDI - Includes Full Library Support)). Programming Options
Import/Export Options
Use New Component Angle Convention - Consult your Universal machine documentation for details about this newer machine placement angle convention. Import - Select this button to import nozzle files in CDI or XML format. Export - Select this button to export nozzle files in CDI or XML format. Pick/Place Nozzles - Displays a list of pick and place nozzles (both imported and user defined if applicable).
For user defined pick and place nozzles, you can specify options such as Name and Description. Consult your Universal machine documentation for details about pick and place nozzle types.
|
CDI - Includes Full Library Support | Feeders | The Feeders tab stores all of the GSM's feeders. On this tab, you create a new feeder to later associate the feeder to a part number.
Note Units are in inches based on the information supplied on the General tab of the Properties dialog.
Categories - Displays a predefined list of available feeder categories such as Coverless Tape, Tape, Matrix, Track, and so on. Groups - Displays user defined list of feeder groups to filter the feeders. Feeders - Displays all available feeders by Category, Group, or Feeder. Name - Displays the name of the selected feeder. Category - Use the drop-down to select a category for the current feeder. Description - Allows you to enter a short description for the selected feeder. Groups - Select the ellipsis (...) to open the Select Group(s) window where you can select one or more groups to which this feeder belongs. Import - Select this button to import Universal feeder files in CI2 or XML format. Export - Select this button to export Universal feeder files in CI2 or XML format.
Consult your Universal machine documentation for details about specific feeder settings. |
CDI - Includes Full Library Support | Components | On the Components tab, you can define information for added components or import component information from a Universal machine. You can also filter compoentns by a user defined group or by avialable category. Categories - Displays a predefined list of available component categories such as BGA, Chip, TAB, Connector, and so on. Groups - Displays user defined list of component groups to filter the components. Part Numbers - Use the tabs to display the currently selected component by Category, Group, or Part Number. Import - Select this button to import Universal component files in CI2 or XML format. Export - Select this button to export Universal component files in CI2 or XML format. Name - Displays the name of the selected component. Category - Use the drop-down to select a category for the current component. Description - Allows you to enter a short description for the selected component. Groups - Select the ellipsis (...) to open the Select Group(s) window where you can select one or more groups to which this feeder belongs. Component-specific data - Use the options in this area to specify data for the currently selected component including:
Consult your Universal machine documentation for details about specific feeder settings. |
CDI - Includes Full Library Support | Comps2 | The Comps2 tab provides access to information regarding the CDI files that are imported from the Universal machine. The dialog contains the same parameters that are available through the Part Number Library on the machine. This dialog allows you to view, enter, and edit the data very easily offline. (Only relevant data is editable depending on the specific part number selected.) The Inspect check box (if selected) allows the machine to inspect the selected component based on the information entered in the Tolerance fields of this dialog (if applicable).
Part Numbers - Displays all available part numbers. Lead Type - Use the drop-down to select a predefined lead type for the selected part number such as J Bend, Gull Wing, UIC A, and so on. Inspection Type - Use the drop-down t o select a predefined inspection type for the selected part number such as 2-Corner High Speed, High Accuracy, High Speed, and so on. Component-specific data - Use the options in this area to specify data for the currently selected component including:
Consult your Universal machine documentation for details about specific component settings. |
CDI - Includes Full Library Support | Comps3 | The Comps 3 tab contains machine information as it relates to specific part numbers. For example, depending on the selected part number, you can adjust head information, camera information, or dispense dot information. Also, depending on the selected part number, you can adjust lead information such as Side, Number of Leads, Lead Pitch, Width, Length, Lead Type and X and Y coordinates. Consult your Universal machine documentation for details about specific feeder settings.
|
CDI - Includes Full Library Support | Configuration | Use the Configuration tab of the Properties dialog to specify the configuration of user-defined feeder banks. Feeder Banks - In this area of the dialog, you can add or delete feeder banks and permanent feeders and define the skip locations to be used.
Note Use the Add and Delete buttons in the dialog to add or delete feeder banks, permanent feeders, and skip locations.
Auto Feeder Setup - This area specifies skip location details for automatic feeders by slot and track/pallet.
Permanent Feeders - Defines permanent feeders for hte Universal machine.
|
Copyright © 2024 Aegis Industrial Software Corporation. All Rights Reserved.