Log into the Production client application.
Select the Advanced Features buttonĀ (the gear) at the top of the window, then select the Measurement Correction button.
Under Filters, specify the filtering criteria to locate the measurement you want to correct.
Identifier is a partial or whole UID; you can also add filters for Measurement Name and Measurement Type in the text boxes at the top of the window.Do one of the following:
Double-click the measurement you want to correct in the table.
Select the measurement you want to correct in the table, then select the Correct Measurement button in the upper-left corner of the window.
Under Sorting on the right side of the window, use the available fields to sort the table information in ascending (ASC) or descending (DSC) order to help you locate the measurement you need to correct.
In the Correct Measurement dialog, enter the new measurement, enter a reason for the change in the Reason For Correction text box, then select OK.
The measurement correction history is displayed in a table in the lower part of the window, including details about when the correction was recorded, who made the change, and the reason for the change.