Barcode Shortcuts in NPI's System Configuration area allow operators to scan printed barcodes that represent functions instead of selecting a function on the workstation screen using a keyboard. For example, a barcode could be generated and printed to send the characters BCSF01. The Production client application interprets the barcode shortcut as the operator selecting

...

the OK

...

 button on the screen at that time. (If no OK button exists on the screen at that time, then nothing happens.)

To view or edit barcode shortcuts in FactoryLogix, use the following procedure.

  1. Log into the NPI client application.

  2. Select System Configuration > Barcode Shortcuts.

...


  1. Barcode Shortcuts windowImage Added



  2. To change a barcode shortcut, select its name in the Barcode Shortcut column. (A pencil icon to the left of the shortcut name indicates that you can edit the name.)

  3. Enter a new name.

  4. To create a keyboard shortcut for a selected barcode shortcut, use the Keyboard Shortcut drop-down to select a keyboard shortcut. (To delete an existing keyboard shortcut, select the "x" next to the shortcut.)

...


  1. Select a keyboard shortcut for a barcode shortcutImage Added


  2. Select Save to save your changes.

  3. (Optional) To restore all default barcode shortcuts, select the Restore Defaults button.

The following table displays the default FactoryLogix barcode shortcuts. (The Keyboard Shortcut column is blank since you assign individual keyboard shortcuts.) 

title
Tip
iconfalse

Tip

For your convenience, you can download and use this Excel file to manage your barcode shortcuts and keyboard shortcut assignments: Barcode Shortcuts.xlsx

Barcode Shortcut

Keyboard Shortcut

Shortcut Type

Shortcut Description

BCSF01


Click OK Button

Automatically clicks an OK button in a dialog

BCSF02


Click Cancel Button

Click Cancel Button (Setup Area)

BCSF05


Start Product

Opens the Start Product Dialog

BCSF06


Pause Product

Fires the Pasue Product Action

BCSF07


Finish Product

Opens the Finish Product Dialog

BCSF08


Clear Product

Fires the Clear Product Action

BCSF09


Log Out

Fires the Log Out Action

BCSF10


Transaction Status Pass

Sets the transaction status to "Pass" when finishing a serial number or quantity

BCSF11


Transaction Status Fail

Sets the transaction status to "Fail" when finishing a serial number or quantity

BCSF12


Scrap Product

Sets the pathway to "Scrap" when finishing a serial number

BCSF13


Next Activity

Selects the next activity

BCSF14


Previous Activity

Select the previous activity

BCSF15


True

Selects "True" in a True/False activity data collection

BCSF16


False

Selects "False" in a True/False activity data collection

BCSF17


Next Document

Selects the next document

BCSF18


Previous Document

Selects the previous document

BCSF19


First Document

Selects the first document

BCSF20


Last Document

Selects the last document

BCSF21


Material Splicing

Opens the Material Splicing window

BCSF22


Material Setup

Opens the Material Setup window

BCSF23


Tracking

Opens the Tracking window

BCSF24


Home

Returns to the Home screen

BCSF25


Trace

Opens the Trace screen

BCSF26


Inventory

Opens the Inventory screen

BCSF27


BOM Viewer

Opens the BOM Viewer window

BCSF28


Enter Key

Simulates clicking the Enter key

BCSF29


Escape Key

Simulates clicking the Escape key

BCSF30


Tab Key

Simlates clicking the Tab key

BCSF31


Shift/Tab Keys

Simulates clicking the Shift and Tab keys simultaneously

BCSF32


Y Key

Simulates clicking the Y key

BCSF33


N Key

Simulates clicking the N key

BCSF34


Activity Completion Acknowledgement

Fires the Activity Completion Acknowledgement  check box

BCSF35


Block UID

Blocks a UID, or uses the default assembly blocking mode if operator choice is not enabled.

BCSF36


Quarantine UID

Quarantines a UID, or uses the default assembly blocking mode if operator choice is not enabled.

BCSF37


Quarantine Then Block UID

Quarantines and then blocks a UID, or uses the default assembly blocking mode if operator choice is not enabled.

BCSF38


Unblock UID

Unblocks a UID

BCSP01


Create New Box

Create a New Box in Packout Area.

BCSP02


Complete a Box

Completes a Box in the Packout Area.

BCSP03


Complete a Partial Box

Completes a Partial Box in the Packout Area.

BCSP04


Clear All Items From a Box

Clears the selected box of all items in the Packout Area.

BCSP05


Reload Packing Items

Reloads all of the Packing items in the Packout Area.

BCSP06


Capture New Box

Toggle Capture New Box mode in the Packout Area.

ClearITT


Clear Indirect Time Track

Clears and discards the current Indirect Time Tracking information.

FTFinishFailed


Finish Full Tracking Mode Status Failed

Finishes Full Tracking Mode with Failed Status.

FTFinishPassed


Finish Full Tracking Mode Status Passed

Finishes Full Tracking Mode with Passed Status.

FTStart


Start Full Tracking Mode

Starts Full Tracking Mode (Non-serialized tracking only).

MTStartFailed


Movement Tracking Mode Status Failed

Sets a Failed status when using the Movement Tracking Mode (Non-serialized tracking only).

MTStartPassed


Movement Tracking Mode Status Passed

Sets a Passed status when using the Movement Tracking Mode (Non-serialized tracking only).

PnlClr


Clear Panel

Clears the panel and its circuit barcodes in the Initialization Gadget.

StartITT


Start Indirect Time Track

Starts Indirect Time Tracking.

StopITT


Stop Indirect Time Track

Stops Indirect Time Tracking.