ADMINISTRATOR
- Locate and open the following file: C:\inetpub\wwwroot\FactoryLogixWebsite\appsettings.json in Notepad or another *.txt file editor.
- On Line 11 "Key", enter a random string of alphanumeric characters which will be used to generate user and session tokens on the server.
- On line 13 “Audience”, enter the address and port of the webserver where the FactoryLogix website will run.
- On line 18 “AppServiceServerName”, enter the name of the server where the FactoryLogix Application Service is running.
- On line 19 “DefaultDatabaseConnectionName”, enter the name of the FactoryLogix database connection.
- Save and close the file.
- Select Start, enter cmd, then select Run as Administrator to open a command prompt window.
- Enter iisreset to restart IIS and update your IIS settings.
When IIS is restarted successfully, you will see a confirmation message.