Barcode Shortcuts in NPI's System Configuration area allow operators to scan printed barcodes that represent functions instead of selecting a function on the workstation screen using a keyboard. For example, a barcode could be generated and printed to send the characters BCSF01. The Production client application interprets the barcode shortcut as the operator selecting the OK button on the screen at that time. (If no OK button exists on the screen at that time, then nothing happens.)

To view or edit barcode shortcuts in FactoryLogix, use the following procedure.

  1. Log into the NPI client application.
  2. Select System Configuration > Barcode Shortcuts.

    Barcode Shortcuts window


  3. To change a barcode shortcut, select its name in the Barcode Shortcut column. (A pencil icon to the left of the shortcut name indicates that you can edit the name.)
  4. Enter a new name.
  5. To create a keyboard shortcut for a selected barcode shortcut, use the Keyboard Shortcut drop-down to select a keyboard shortcut. (To delete an existing keyboard shortcut, select the "x" next to the shortcut.)

    Select a keyboard shortcut for a barcode shortcut

  6. Select Save to save your changes.
  7. (Optional) To restore all default barcode shortcuts, select the Restore Defaults button.


The following table displays the default FactoryLogix barcode shortcuts. (The Keyboard Shortcut column is blank since you assign individual keyboard shortcuts.) 


Tip

For your convenience, you can download and use this Excel file to manage your barcode shortcuts and keyboard shortcut assignments: Barcode Shortcuts.xlsx

Barcode ShortcutKeyboard ShortcutShortcut TypeShortcut Description
BCSF01
Click OK ButtonAutomatically clicks an OK button in a dialog
BCSF02
Click Cancel ButtonClick Cancel Button (Setup Area)
BCSF05
Start ProductOpens the Start Product Dialog
BCSF06
Pause ProductFires the Pasue Product Action
BCSF07
Finish ProductOpens the Finish Product Dialog
BCSF08
Clear ProductFires the Clear Product Action
BCSF09
Log OutFires the Log Out Action
BCSF10
Transaction Status PassSets the transaction status to "Pass" when finishing a serial number or quantity
BCSF11
Transaction Status FailSets the transaction status to "Fail" when finishing a serial number or quantity
BCSF12
Scrap ProductSets the pathway to "Scrap" when finishing a serial number
BCSF13
Next ActivitySelects the next activity
BCSF14
Previous ActivitySelect the previous activity
BCSF15
TrueSelects "True" in a True/False activity data collection
BCSF16
FalseSelects "False" in a True/False activity data collection
BCSF17
Next DocumentSelects the next document
BCSF18
Previous DocumentSelects the previous document
BCSF19
First DocumentSelects the first document
BCSF20
Last DocumentSelects the last document
BCSF21
Material SplicingOpens the Material Splicing window
BCSF22
Material SetupOpens the Material Setup window
BCSF23
TrackingOpens the Tracking window
BCSF24
HomeReturns to the Home screen
BCSF25
TraceOpens the Trace screen
BCSF26
InventoryOpens the Inventory screen
BCSF27
BOM ViewerOpens the BOM Viewer window
BCSF28
Enter KeySimulates clicking the Enter key
BCSF29
Escape KeySimulates clicking the Escape key
BCSF30
Tab KeySimlates clicking the Tab key
BCSF31
Shift/Tab KeysSimulates clicking the Shift and Tab keys simultaneously
BCSF32
Y KeySimulates clicking the Y key
BCSF33
N KeySimulates clicking the N key
BCSF34
Activity Completion AcknowledgementFires the Activity Completion Acknowledgement  check box
BCSF35
Block UIDBlocks a UID, or uses the default assembly blocking mode if operator choice is not enabled.
BCSF36
Quarantine UIDQuarantines a UID, or uses the default assembly blocking mode if operator choice is not enabled.
BCSF37
Quarantine Then Block UIDQuarantines and then blocks a UID, or uses the default assembly blocking mode if operator choice is not enabled.
BCSF38
Unblock UIDUnblocks a UID
BCSP01
Create New BoxCreate a New Box in Packout Area.
BCSP02
Complete a BoxCompletes a Box in the Packout Area.
BCSP03
Complete a Partial BoxCompletes a Partial Box in the Packout Area.
BCSP04
Clear All Items From a BoxClears the selected box of all items in the Packout Area.
BCSP05
Reload Packing ItemsReloads all of the Packing items in the Packout Area.
BCSP06
Capture New BoxToggle Capture New Box mode in the Packout Area.
ClearITT
Clear Indirect Time TrackClears and discards the current Indirect Time Tracking information.
FTFinishFailed
Finish Full Tracking Mode Status FailedFinishes Full Tracking Mode with Failed Status.
FTFinishPassed
Finish Full Tracking Mode Status PassedFinishes Full Tracking Mode with Passed Status.
FTStart
Start Full Tracking ModeStarts Full Tracking Mode (Non-serialized tracking only).
MTStartFailed
Movement Tracking Mode Status FailedSets a Failed status when using the Movement Tracking Mode (Non-serialized tracking only).
MTStartPassed
Movement Tracking Mode Status PassedSets a Passed status when using the Movement Tracking Mode (Non-serialized tracking only).
PnlClr
Clear PanelClears the panel and its circuit barcodes in the Initialization Gadget.
StartITT
Start Indirect Time TrackStarts Indirect Time Tracking.
StopITT
Stop Indirect Time TrackStops Indirect Time Tracking.


  • No labels