The Logistics tab in the Part Library window is used to manage material handling for IPN electronics parts. 

  1. Log into the NPI client application.
  2. Select Libraries Libraries button > Part Library.
  3. On the Internal Part Number tab, select an Internal Part Number, then select the Logistics tab on the right side of the window.
  4. Specify the Logistics options for that part (see the following table for details about Logistics options).
  5. Select the Save button at the bottom of the window.

    Logistics tab

Logistics tab options

ItemDescription
Receiving Process

Specifies the receiving process for this part.

  1. Select the magnifying glass button to search for previously-saved receiving processes.

    Please Select a Receiving Process dialog

  2. Select a receiving process in the Please Select a Receiving Process dialog, then select OK.

    Note:

    Select the Clear button (the Red x) if you want to remove the current receiving process.

Kitting Type

Kitting is the gathering of parts and other components needed to manufacture an assembly or product. Individual components are gathered into a kit that is delivered to the point of use in the factory. Kitting typically functions in a series of steps.

Select None, Kitted, or Not Kitted for the Kitting Type.

Reservation Type

A reservation is a guaranteed allotment of material to a supply source.

Select UID, Quantity, or Flexible Quantity for the Reservation Type.

Default Stock Location

Specifies the location in your factory where the selected part is stocked and available for use in Production.

Note:

You set up stock locations as resources in the Factory Resources area of NPI. 

Packaging SizeSpecifies the size of the package if this part is stocked in packaged quantities.
Component TypeSpecifies the component type of the selected part: Capacitor, Coil, Diode, Polarized Tantalum Capacitor, ResistorTantalum Capacitor, Unknown, or Zener Diode.
Nominal Value Detail

Represents the normal value of the part in question.

Note:

This is a legacy option and is not used by FactoryLogix. 

Maximum Baking Count

Sets the number of times a moisture sensitive part can be baked to remove moisture content before it can no longer be used.

Default Baking Time (seconds)Specifies the default baking time (in seconds) for the selected part.
MSD Level

Specifies the acceptable moisture sensitivity level for the selected part.


Important!

MSD settings control MSD exposure at the point of use. If a user has an “open” MSD part for longer than the maximum exposure time allows, the system will not allow that material to be loaded for Material Setup and will invalidate the material at any location where it is currently set up. 


  1. Select the Edit MSD (gear)  button to display the MSD Level dialog.
  2. Select the moisture sensitivity level for this part under Available MSD Levels.
  3. (Optional) Add a comment in the Comment field.
  4. Select the Open Period drop-down, then specify how long a part will be exposed before it must be baked to remove moisture from it.

    Note:

    Open time (also referred to as exposure time) defines how long a particular part can be exposed to the ambient air before it must be baked to remove the moisture from it.


  5. When you are finished configuring the MSD level options, select OK.


MSD Level dialog

Solder Paste Profile

Specifies the solder paste profile for the selected part.

  1. Select the Edit Solder Paste Profile (gear) button to display the Solder Paste Profiles dialog. 
  2. Enter a Name for the Profile, specify the Minimum Time and Maximum Time values for the profile, then select OK.


Solder Paste Profiles dialog


Component Handling

Specifies how the selected component part will be handled in the manufacturing process. For example, some parts must be glued to other parts or components, while other parts may need to be scrapped if a placement error occurs during manufacturing.


Component Handling selections