After you add programming to your FactoryLogix assembly, you select the Setup machine Setup button  for every assembly before you generate a machine program. The purpose of the machine Setup dialog is to teach the fiducial shapes and allow you to add any new part numbers to the Fuji database.


Fuji Nexim - Part Management and Troubleshooting


  1. To access the Fuji Nexim Setup dialog, select Part Management and Troubleshooting in the Machine List window (in the Process Definition window).
  2. Select the Setup Setup button button.

    Fuji Nexim Setup dialog

  3. (Optional) Use CAD Coordinates is a setting that will try and take the coordinates imported from the CAD file and export them into the generated machine program/ This setting ignores any origin set in the Board Geometry area or the ECAD view in the Process Definition window. 

    Setup buttons and check boxes

  4. (Optional) Select the Populate Missing Part Descriptions button to add
  5. (Optional) To treat all images in the Process Definition window as a single board, select the Treat All Images as Single Board check box.
  6. (Optional) Select the Clear Setup Clear Setup button button to erase machine setup settings. When the confirmation message displays, select Yes to clear all the Setup dialog settings.

    Clear Setup message


    Tip

    The Clear Setup button can be very useful. If there are problems with the generated program, use the Clear Setup button and proceed through the machine interface again to address potential rotational, location, and assignment problems.


  • No labels