The following tables describe the available adapter settings you can specify for a selected inForce xLink adapter on the Settings tab of the xLink Servers window in NPI.
To access the xLink Servers window, log into the NPI client application, then select System Configuration > xLink Configuration.
Property Description Upstream Machine Serial Number Specifies the user-entered serial number of the machine located upstream from the selected inForce 2.0 device. Note Leave the serial number field blank if the upstream machine doesn't generate events. The bookending modes are determined using the upstream machine serial number, downstream machine serial number, and downstream eventing settings. If you specify the upstream machine's serial number, an Item Transfer Out (ITO) will be generated. Downstream Eventing Specifies the downstream xLink adapter settings. In order to have a complete WIP transaction in FactoryLogix, at least three events must be present – IIR, ITI, and ITO. (Select All) - Selects all downstream options IIR - Item Identifier Read ITI - Item Transfer In ITO - Item Transfer Out Disable Passcode Specifies a four-digit PIN that allows the inForce device to be disabled (Bypass mode). Note To disable security, set the PIN to 0000. Administrator Passcode Specifies a four- to seven-digit PIN that allows the device that restricts access to device configurations. Note To disable security, set the PIN to 0000. Failed Barcode Scan Retry Count Specifies the number of times to attempt to read a barcode before sounding an audible alarm. Enable Alarm Tower Sound Enables/disables the alarm tower sound. Enable Barcode Scanning Enables/disables capturing barcodes from a barcode scanner. PCB Verifier IP Address Specifies the IP address or machine name of the workstation running PCB Verifier (leave blank to disable this property). PCB Verifier IP Port Specifies the port number configured in PCB Verifier that allows PCB Verifier to communicate with the selected inForce adapter. Set Active Batch for Workstations A list of workstations (FactoryLogix resource names) separated by semicolons ;. If you set this property to a non-empty value, the active batch will be set for each listed workstation by this xLink adapter. Property Description Validate Entry Conditions Validates a scanned barcode to indicate that the product can be started at the associated operation. Validate Line Stop Validates whether there is a line stop at the workstation. Validate Material Setup Validates that all materials have been loaded. Validate Workstation Restriction Validates whether the scanned board should be allowed to be scanned at this workstation. Validate Route Validates whether the scanned board should be allowed to be scanned at this operation. Property Description Max Retry Count Specifies the maximum number of times to retry the entry condition validation before notifying the operator. The default value is 0. Retry Delay (ms) Specifies the amount of time (in ms) to wait before attempting entry condition validation. The default value is 1000 ms (=1 second). Property Description Board Available Upstream Logic Specifies the signal that prompts inForce to begin listening for a barcode: Normal logic indicates an upstream Board Available signal to the inForce device when the appropriate contacts are CLOSED (set HIGH). When set to Inverted, the Board Available signal is indicated to inForce when the appropriate contacts are OPEN (set LOW). Board Available Downstream Logic Specifies the signal logic to use for the Board Available SMEMA signal. Normal logic outputs a downstream Board Available signal by CLOSING the appropriate contacts to the downstream equipment (set HIGH). Inverted logic outputs a downstream Board Available signal by OPENING the appropriate contacts to the downstream equipment (set LOW). Machine Ready Upstream Logic Specifies the signal logic to use for the Machine Ready SMEMA signal. Normal logic outputs an upstream Machine Ready signal by CLOSING the appropriate contacts to the upstream equipment (set HIGH). Inverted logic outputs an upstream Machine Ready signal by OPENING the appropriate contacts to the upstream equipment (set LOW). Machine Ready Downstream Logic Specifies the signal logic to use for the Machine Ready SMEMA signal. Normal logic indicates a downstream Machine Ready signal to the inForce device when the appropriate contacts are CLOSED (set HIGH). Board Fail Upstream Logic (Used in conjunction with the Diverter options.) Specifies the signal logic to use for the Board Fail SMEMA signal. Normal logic indicates an upstream Failed Board Available signal to the inForce device when the appropriate contacts are CLOSED (set HIGH). When set to Inverted, the Failed Board Available signal is indicated to inForce when the appropriate contacts are OPEN (set LOW) Board Fail Downstream Logic (Used in conjunction with the Diverter options.) Specifies the signal logic to use for the Board Fail SMEMA signal. Normal logic outputs a downstream Failed Board Available signal by CLOSING the appropriate contacts to the downstream equipment (set HIGH). Inverted logic outputs a downstream Failed Board Available signal by OPENING the appropriate contacts to the downstream equipment (set LOW). Property Description Enable Serial Port Transmission Enables or disables sending barcodes via a Serial port. Baud Rate Specifies the baud rate of the serial port (9600, for example). Data Bits Specifies the number of data bits in each character value transmitted or received. This value does not include stop bits or parity bits. Stop Bits Specifies the standard number of stop bits per byte: 0 - One - One stop bit is used. 1 - One Point Five - 1.5 stop bits are used. 2 - Two - 2 stop bits are used. Handshake The hardware handshake protocol for flow control: None - No control is used for the handshake. Request To Send - Request To Send (RTS) hardware flow control is used for the handshake. XOn/XOff - The XON/XOFF software protocol control is used for the handshake. Request To Send XOn/XOff - Both the Request To Send (RTS) and the XON/XOFF software controls are used for the handshake. Parity Specifies the parity bit for error checking: None - No parity check occurs. Odd - Sets the parity bit so that the count of bits is an odd number. Even - Sets the parity bit so that the count of bits is an even number. Mark - Leaves the parity bit set to 1. Space - Leaves the parity bit set to 0. Write Timeout (ms) Specifies the timeout value for a Write operation in milliseconds (ms). The default value is 1000 milliseconds (=1 second). Read Timeout (ms) Specifies the timeout value for a Read operation in milliseconds (ms). The default value is 1000 milliseconds (=1 second). Transmission Delay (ms) Specifies the number of milliseconds (ms) to delay before transmitting to the serial port. The default is 500 milliseconds. Transmission Mode Specifies the mode that determines when to transmit to the serial port: After Barcode Validation - when a barcode is received After Item Transferred - after the barcode is transferred) Wait to Receive LON Command From Machine When selected, specifies that a LON command must be received from the machine before transmitting to the serial port. Enable Post Barcode Processing Enables/disables post processing when receiving barcodes. Note Enable Post Barcode Processing is a legacy setting which should be set to OFF under most circumstances. Post Barcode Processing RegEx A regular expression to use for removing unwanted characters from a barcode that was received. Preambles The set of characters at the start of a barcode for serial transmission. You can use a combination of numeric, alpha-numeric, and decimal characters. Aegis supports any decimal characters by the following method '<##>'. < indicates the start of a decimal character. ## is the actual decimal number of the character. > indicates the end of the decimal character. Note All decimal numbers are translated to their hexadecimal equivalents. Postambles The set of characters at the end of a barcode for serial transmission. You can use a combination of numeric, alpha-numeric, and decimal characters. Aegis supports any decimal characters by the following method '<##>'. < indicates the start of a decimal character. ## is the actual decimal number of the character. > indicates the end of the decimal character. Note All decimal numbers are translated to their hexadecimal equivalents. Property Description Enable Diverting Conveyor Logic When selected, the downstream BOARD FAIL signal controls diverting units that fail route validation. Diverter Workstations A semicolon-separated ; list of allowable workstations (FactoryLogix resource names) into the diverter; otherwise the unit will wait to be removed manually from the conveyor line. Note If you leave this property blank, all failed route validations will be diverted. Property Description Enable Remote inForce Logging When selected, enables event logging from the inForce console unit to the Service log under the Debug Level.Adapter options
Validation options
Entry Condition Retry Settings
SMEMA Signal Logic Options
Serial Port Options
RTS signals that data is available for transmission. If the input buffer fills up, the RTS line will be set to False. The RTS line will be reset to True when more room is available in the input buffer.
The XOFF control is sent to stop data transmission. The XON control is sent to resume data transmission. These controls are used instead of Request To Send (RTS) and Clear To Send (CTS) hardware controls.Diverter Options
Debug Options